T1 - Mean glandular dose in six digital mammography services in santiago, Chile
T2 - Preliminary reference levels
AU - Leyton, Fernando
AU - Nogueira, Maria Do Socorro
AU - Dantas, Marcelino
AU - Duran, Maria Paz
AU - Ubeda, Carlos
N1 - Publisher Copyright:
© The Author 2015.
PY - 2015/7/1
Y1 - 2015/7/1
N2 - The purpose of this paper was to estimate mean glandular dose levels (DG) in six digital mammography systems in Santiago, Chile, and to propose preliminary reference levels to execute mammography in Chile. The study was carried out assessing two direct digital systems and four computer-based radiography (CR) systems. Estimates of DG were calculated for different thicknesses of polymethyl methacrylate according to the quality control protocol in digital mammography of the Spanish Society of Medical Physics and NHSBSP Equipment Report 0604 Version 3. DG values ranged between 0.64 and 7.26 mGy for a range of 20- to 70-mm thickness, respectively. Thirty-six per cent of DG was higher than the acceptable dose level and 100 % of DG was higher than the desirable level. It is therefore necessary to optimise doses. The initial proposal to establish dose reference levels for DG would range between 0.90 and 6.40 mGy for a thickness range of 20 to 70 mm.
AB - The purpose of this paper was to estimate mean glandular dose levels (DG) in six digital mammography systems in Santiago, Chile, and to propose preliminary reference levels to execute mammography in Chile. The study was carried out assessing two direct digital systems and four computer-based radiography (CR) systems. Estimates of DG were calculated for different thicknesses of polymethyl methacrylate according to the quality control protocol in digital mammography of the Spanish Society of Medical Physics and NHSBSP Equipment Report 0604 Version 3. DG values ranged between 0.64 and 7.26 mGy for a range of 20- to 70-mm thickness, respectively. Thirty-six per cent of DG was higher than the acceptable dose level and 100 % of DG was higher than the desirable level. It is therefore necessary to optimise doses. The initial proposal to establish dose reference levels for DG would range between 0.90 and 6.40 mGy for a thickness range of 20 to 70 mm.
UR - https://www.scopus.com/pages/publications/84939529131
U2 - 10.1093/rpd/ncv092
DO - 10.1093/rpd/ncv092
M3 - Article
C2 - 25833896
AN - SCOPUS:84939529131
SN - 0144-8420
VL - 165
SP - 115
EP - 120
JO - Radiation Protection Dosimetry
JF - Radiation Protection Dosimetry
IS - 1-4
ER -