T1 - Latin American image quality survey in digital mammography studies
AU - Mora, Patricia
AU - Khoury, Helen
AU - Bitelli, Regina
AU - Quintero, Ana Rosa
AU - Garay, Fernando
AU - Aguilar, Juan García
AU - Gamarra, Mirtha
AU - Ubeda, Carlos
N1 - Publisher Copyright:
© The Author 2016. Published by Oxford University Press. All rights reserved.
PY - 2017/4/20
Y1 - 2017/4/20
N2 - Under International Atomic Energy Agency regional programme TSA3 Radiological Protection of Patients in Medical Exposures, Latin American countries evaluated the image quality and glandular doses for digital mammography equipment with the purpose of seeing the performance and compliance with international recommendations. Totally, 24 institutions participated from Brazil, Chile, Costa Rica, El Salvador, Mexico, Paraguay and Venezuela. Signal difference noise ratio results showed for CR poor compliance with tolerances; better results were obtained for full-field digital mammography equipment. Mean glandular dose results showed that the majority of units have values below the acceptable dose levels. This joint Latin American project identified common problems: difficulty in working with digital images and lack of specific training by medical physicists from the region. Image quality is a main issue not being satisfied in accordance with international recommendations; optimisation processes in which the doses are increased should be very carefully done in order to improve early detection of any cancer signs.
AB - Under International Atomic Energy Agency regional programme TSA3 Radiological Protection of Patients in Medical Exposures, Latin American countries evaluated the image quality and glandular doses for digital mammography equipment with the purpose of seeing the performance and compliance with international recommendations. Totally, 24 institutions participated from Brazil, Chile, Costa Rica, El Salvador, Mexico, Paraguay and Venezuela. Signal difference noise ratio results showed for CR poor compliance with tolerances; better results were obtained for full-field digital mammography equipment. Mean glandular dose results showed that the majority of units have values below the acceptable dose levels. This joint Latin American project identified common problems: difficulty in working with digital images and lack of specific training by medical physicists from the region. Image quality is a main issue not being satisfied in accordance with international recommendations; optimisation processes in which the doses are increased should be very carefully done in order to improve early detection of any cancer signs.
UR - https://www.scopus.com/pages/publications/85019070038
U2 - 10.1093/rpd/ncw049
DO - 10.1093/rpd/ncw049
M3 - Article
C2 - 27009246
AN - SCOPUS:85019070038
SN - 0144-8420
VL - 174
SP - 94
EP - 101
JO - Radiation Protection Dosimetry
JF - Radiation Protection Dosimetry
IS - 1
M1 - ncw049
ER -