T1 - Dose estimation by geant4-based simulations for cone-beam ct applications
T2 - A systematic review
AU - Cabanas, Ana M.
AU - Arriagada-Benítez, Mauricio
AU - Ubeda, Carlos
AU - Meseguer-Ruiz, Oliver
AU - Arce, Pedro
N1 - Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021/7/1
Y1 - 2021/7/1
N2 - The last two decades have witnessed increasing use of X-ray imaging and, hence, the exposure of humans to potentially harmful ionizing radiation. Computed tomography accounts for the largest portion of medically-related X-ray exposure. Accurate knowledge of ionizing radiation dose from Cone-Beam CT (CBCT) imaging is of great importance to estimate radiation risks and justification of imaging exposures. This work aimed to review the published evidence on CBCT dose estimation by focusing on studies that employ Geant4-based toolkits to estimate radiation dosage. A systematic review based on a scientometrics approach was conducted retrospectively, from January 2021, for a comprehensive overview of the trend, thematic focus, and scientific production in this topic. The search was conducted using WOS, PubMed, and Scopus databases, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. In total, 93 unique papers were found, of which only 34 met the inclusion criteria. We opine that the findings of this study provides a basis to develop accurate simulations of CBCT equipment for optimizing the trade-off between clinical benefit and radiation risk.
AB - The last two decades have witnessed increasing use of X-ray imaging and, hence, the exposure of humans to potentially harmful ionizing radiation. Computed tomography accounts for the largest portion of medically-related X-ray exposure. Accurate knowledge of ionizing radiation dose from Cone-Beam CT (CBCT) imaging is of great importance to estimate radiation risks and justification of imaging exposures. This work aimed to review the published evidence on CBCT dose estimation by focusing on studies that employ Geant4-based toolkits to estimate radiation dosage. A systematic review based on a scientometrics approach was conducted retrospectively, from January 2021, for a comprehensive overview of the trend, thematic focus, and scientific production in this topic. The search was conducted using WOS, PubMed, and Scopus databases, according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. In total, 93 unique papers were found, of which only 34 met the inclusion criteria. We opine that the findings of this study provides a basis to develop accurate simulations of CBCT equipment for optimizing the trade-off between clinical benefit and radiation risk.
KW - Bibliometrics
KW - Cone-beam computed tomography
KW - Dosimetry
KW - Geant4
KW - Monte carlo simulations
KW - Radiation exposure
KW - Radiation protection
KW - Systematic-review
UR - https://www.scopus.com/pages/publications/85109882775
U2 - 10.3390/app11136136
DO - 10.3390/app11136136
M3 - Review article
AN - SCOPUS:85109882775
SN - 2076-3417
VL - 11
JO - Applied Sciences (Switzerland)
JF - Applied Sciences (Switzerland)
IS - 13
M1 - 6136
ER -