TY - JOUR
T1 - Characterization and experimental measurements of scatter dose at cardiologist's eyes during paediatric interventional cardiology procedures in Costa Rica
AU - Ubeda, Carlos
AU - Salazar, Luisa
AU - Retana, Viviana
AU - Santos, Freddy
AU - Salvador, Lourdes
AU - Sáenz, Carlos
AU - Quesada, Cristhian
AU - Gavarrete, Manuel
AU - Picado, Marcela
AU - Arce, Luis
N1 - Publisher Copyright:
© The Author 2017. Published by Oxford University Press. All rights reserved.
PY - 2017/11/1
Y1 - 2017/11/1
N2 - This paper presents the results of the first characterization and experimental measurements of scatter dose at cardiologist's eyes for the only X-ray system that performs all paediatric Interventional cardiology procedures in Costa Rica. Entrance surface air kerma (ESAK) and the scatter dose values were measured on phantoms of 4-20 cm thicknesses of polymethyl methacrylate slabs. Image quality was evaluated using DICOM images of a test object Leeds TOR 18-FG, through the numerical parameters signal-to-noise ratio (SNR), high-contrast spatial resolution (HCSR) and figure of merit (FOM). When PMMA thickness is increased and during a move from low fluoroscopy to cine modes, ESAK, SNR, HCSR and FOM values range from 0.44 to 391.0 μGy fr-1; 2.8 to 14.89; 3.17 to 15.54 and 0.51 to 79.94, respectively. The highest scattered dose rates recorded during the simulations were 1.79 and 8.04 mSv h-1 for the high fluoroscopy and cine modes, respectively.
AB - This paper presents the results of the first characterization and experimental measurements of scatter dose at cardiologist's eyes for the only X-ray system that performs all paediatric Interventional cardiology procedures in Costa Rica. Entrance surface air kerma (ESAK) and the scatter dose values were measured on phantoms of 4-20 cm thicknesses of polymethyl methacrylate slabs. Image quality was evaluated using DICOM images of a test object Leeds TOR 18-FG, through the numerical parameters signal-to-noise ratio (SNR), high-contrast spatial resolution (HCSR) and figure of merit (FOM). When PMMA thickness is increased and during a move from low fluoroscopy to cine modes, ESAK, SNR, HCSR and FOM values range from 0.44 to 391.0 μGy fr-1; 2.8 to 14.89; 3.17 to 15.54 and 0.51 to 79.94, respectively. The highest scattered dose rates recorded during the simulations were 1.79 and 8.04 mSv h-1 for the high fluoroscopy and cine modes, respectively.
UR - https://www.scopus.com/pages/publications/85042566799
U2 - 10.1093/rpd/ncx031
DO - 10.1093/rpd/ncx031
M3 - Article
C2 - 28369635
AN - SCOPUS:85042566799
SN - 0144-8420
VL - 176
SP - 450
EP - 455
JO - Radiation Protection Dosimetry
JF - Radiation Protection Dosimetry
IS - 4
ER -